Specifications & Description

  • Capacity (cu ft)2.3
  • Capacity (Liters)66
  • Control TypeMicroprocessor
  • Max Temperature (° C)105
  • Temperature Stability± 0.1°C at 37°C
  • Overall Depth (in)22 1/4
  • Overall Depth (cm)56.5
  • Overall Height (in)28 5/16
  • Overall Height (cm)71.9
  • Overall Width (in)20 7/8
  • Overall Width (cm)53
  • Power (VAC)120
  • Power (Hz)60
  • Power (watts)1390
  • Chamber Depth (in)14 1/2
  • Chamber Depth (cm)36.8
  • Chamber Height (in)20
  • Chamber Height (cm)50.8
  • Chamber Width (in)13 7/8
  • Chamber Width (cm)35.2
  • Display TypeVacuum Fluorescent
  • Number Of Shelves2
  • Number Of Shelf Positions13
  • Internal ConstructionStainless steel
  • AlarmAudible
  • Timer RangeWeekly / Hourly / Real Time
  • DescriptionAdvanced Security Incubator, 2 cu ft, Dual; 120V
  • Warranty2 year
Two year warranty

Key Features

  • Dual convection for application versatility — adjustable fan speed from 10 to 100%
  • Advanced digital timer for daily or weekly on/off cycles
  • Additional safety features for ultimate sample protection
  • 2 year warranty

More About this Item

Incubators include additional safety features for essential sample protection: a lockable door for restricted access, an alarm sounds if the door is left open accidentally, and an automatic over-and under-temperature alarm. Broad temperature range from 5°C above ambient to 105°C is suitable for drying applications. One-of-a-kind 140°C contamination cycle reduces microorganism to a minimum — comparable to sterilization — within a six-hour heating cycle. With the 140°C contamination cycle there is no need for separate autoclaving of internal fittings. Units have an easy-to-clean stainless steel interior, large easy-to-read vacuum fluorescent display, and internal glass door to allow sample viewing without impacting temperature.